air cooled big capacity Hanbell compressor-20c temperature let out water hospital central water chiller

Quantity:
  • Manufacturing Plant, Food & Beverage Factory, Farms, Printing Shops, Construction works

  • None

  • Provided

  • Provided

  • Hot Product 2019

  • 1 Year

  • compressor

  • NEW

  • Air-cooled

  • China

  • Lechang

  • 380V/50HZ/3PH

  • 2650*850*1750mm

  • 980 KG

  • 1 Year

  • 90KW

  • High Productivity

  • 30HP air cooled chiller

  • 90kw

  • R22/R407C/R134A/R410A

  • CE

  • copeland

  • Finned copper tube+ low noise outer rotor fan

  • shell & tube

  • 0.7KW*2

  • industrial refrigeration

  • 380V/50HZ/3PH

30HP Air cooled chiller

Model

Item

LC-30A

Band

Power supply

380V/3PH/50HZ

Nominal cooling capacity

Kcal/h

77130

kw

90

Refrigerant

Name

R22(or R407C/R404A)

Import of high quality refrigerant

Control method

Thermostatic expansion valve

Compressor

Type

Scroll compressor

Copeland(America)

Power(HP)

10*3

Condenser

Type

Finned copper tube+low noise outer rotor fan

High efficiency Finned copper tube heat exchanger

Cooling air flow(m3/h)

35400

Power(kw)

0.7*3

Environment Temp(dissipate heat

≤45℃

Evaporator

Type

Shell tube

Shell tube

Chilled water flow (L/min)

650

Inlet/out pipe caliber

21/2

Water pump

Power(HP)

3

Muchuan

Lift(m)

16

Safety protection

Control pane

Compressor overheating

protection,over-current

protection,high and low

pressure protection,over temperature protection,

flow switch protection,phase sequence or missing phase

protection, exhaust overheating protection,antifreezing

protection.

Punp

High/low pressure gauge

JAVE(Taiwan)

Filter

ALCO(America)

Relay

Schneider(France)

Contactor

Schneider(France)

Power switch

Chint

Dimension

weight(kg)

980

Wooden case

LxWxH(mm)

2650*850*1750

Surface treatment

Mainboard :2mm, closingboard: 1.5mm

Baking varnish

Remark:


1.The cooling capacity is based on: chilled water inlet and outlet water temperature 12 ° C / 7 ° C, cooling inlet and outlet water temperature 30 ° C / 35 ° C

2.range of work:Chilled water(Temp range):5℃-35℃;inlet and outlet water(temp range) :3℃-8℃.working environment: ≤35℃(condensation Temp)

3.Conversion of units:1kw cooling capacity=860kcal/hr

1RT=3024kcal/hr 1kcal/hr=3.969BTU/hr 1HP=0.735KW

PRODUCT PICTURES

air cooled big capacity Hanbell compressor-20c temperature let out water hospital central water chiller air cooled big capacity Hanbell compressor-20c temperature let out water hospital central water chiller

OUR FACTORY

OUR CERTIFICATE

air cooled big capacity Hanbell compressor-20c temperature let out water hospital central water chiller

air cooled big capacity Hanbell compressor-20c temperature let out water hospital central water chiller

air cooled big capacity Hanbell compressor-20c temperature let out water hospital central water chiller

Previous: 
Next: 

Get A Free Quote

Get A Free Quote

Please contact us with any questions you may have by filling out and sending the form below.

Home
 Copyrights 2021   Lechang  All rights reserved.   Support By LeadongSitemap   粤ICP备2022010800号